High-voltage battery

# HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66 / aluminium alloy

NOMINAL ENERGY  8–48 kWh

BATTERY VOLTAGE  Confirm selected configuration

[Start your project ↗](https://ke.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Max. DC (kW) |
| --- | --- | --- |
| HP Ultra-8.0 | 8 | 4 |
| HP Ultra-16.0 | 16 | 8 |
| HP Ultra-24.0 | 24 | 12 |
| HP Ultra-32.0 | 32 | 16 |
| HP Ultra-40.0 | 40 | 20 |
| HP Ultra-48.0 | 48 | 24 |

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 |
| HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 |
| HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 |
| HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 |
| HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 |
| HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 |

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

## A highland home and a coastal home have different storage needs.

Kenya spans temperate highlands, hotter humid coastal areas and arid or semi-arid lowlands. Plan a useful energy reserve around your household loads, then choose the battery format and a protected equipment space for your particular location.

Temperature:  Confirm selected configuration

ENCLOSURE  IP66 / aluminium alloy

01

### Highland home with a dedicated service room

For a home office, refrigeration and selected lights, a dry indoor utility space can keep the system close to the circuits it serves and leave straightforward service access.

An EU integrated system brings battery and inverter together. A TR Pro 51.2 V battery can instead work with a confirmed compatible existing inverter; size energy for the hours you choose and retain the selected model’s clearances.

Which circuits and backup hours would you like to plan for?

- What are the minimum and maximum temperatures inside the proposed room?

02

### Coastal home with a sheltered equipment area

The hotter, more humid coast calls for attention to a room’s airflow, rain exposure and coastal air. A protected service room gives refrigeration, fans and connectivity a practical installation setting.

TR Pro provides compact 51.2 V storage; HP Ultra provides a modular high-voltage format. Both list IP66. Select the architecture to match the inverter, with shelter and environmental conditions reviewed for the exact model.

Can rain, condensation, wash water or coastal air reach the equipment?

- Is the inverter a 51.2 V or high-voltage battery system?

03

### Warmer inland site with more dust exposure

In a warmer or dusty inland location, an enclosed dry equipment area with clear airflow helps keep the battery installation accessible and protected from everyday activity.

Choose wall or floor-mounted storage to suit available service space. Review the actual enclosure option and room temperature: standard TR and HP K list IP20 with IP54 optional, while HP Ultra needs its temperature range confirmed for the selected configuration.

How will dust ingress and the room’s heat be managed?

- Can cooling paths, fixing points and power/communication routes remain clear?

Specifications

- Pair energy and power: kWh helps plan duration, while the compatible inverter’s kW rating, battery limits and starting-load capability determine which circuits can run together.

- TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature limits require configuration-specific confirmation. Check the room, rather than a national temperature label.

- Specify shelter and the exact enclosure. IP66 does not itself establish flood, condensation or coastal-corrosion suitability; source temperature limits do not guarantee full output at every temperature.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

[![DC electrical / heatsink face - original callouts](https://ke.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://ke.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)

DC electrical / heatsink face - original callouts  DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.

[![Communication and parallel-interface face - original callouts](https://ke.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://ke.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)

Communication and parallel-interface face - original callouts  Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.

[![Communication-side detail (partial oblique view)](https://ke.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://ke.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)

Communication-side detail (partial oblique view)  Oblique detail of the stack's communication-side connector area.

[![Module top / mating surfaces](https://ke.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://ke.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)

Module top / mating surfaces  Battery module top and mating surfaces.

### Know your interfaces.

#### Power connections

Positive Pole  Positive terminal identified by the original leader line on the electrical face.

Negative Pole  Negative terminal identified by the original leader line on the electrical face.

#### Communication

Bluetooth/WIFI Antenna  Antenna label on the upper communication-side area.

Backup Com  The brochure labels this connection 'Backup Com' but does not explain its exact role.

INV CAN/RS485 Com  The INV-labelled CAN/RS485 communication connection shown in the original diagram.

Parallel COM1  First parallel-communication label near the lower part of the illustrated interface face.

Parallel COM2  Second parallel-communication label near the lower part of the illustrated interface face.

#### Controls & indicators

Switch  Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.

DC Breaker  DC breaker on the electrical / heatsink face.

Breathing Light  Light strip called out at the upper front portion in the oblique construction view.

#### Structure & mounting

Heat Dissipation Aluminum Plate  Heat-dissipation aluminum plate called out on the slim electrical-side illustration.

Wall Mounted Bracket  Mounting brackets shown on the vent-side illustration.

PDU  PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.

Module  Repeated battery sections below the top PDU.

Base  Base at the bottom of the illustrated stack.

BMS Debugging Interface  BMS debugging interface identified on the communication-side illustration.

Pressure Relief Valve  Pressure-relief component called out in the communication-side oblique view.

GND  Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10

---

https://ke.elvorka.com/en/products/hp-ultra/

ELVORKA · eric@elvorka.com