# TA6000.

![TA6000](https://ke.elvorka.com/assets/optimized/3767e02b99d59eea-1254-q92.webp)

Integrated system

# TA6000.

Battery and inverter in one cabinet, with PV input connectivity and three specified storage configurations. AC output options depend on the selected configuration.

INVERTER  Included

ENCLOSURE  Not specified

NOMINAL ENERGY  10.24–20.48 kWh

AC CONFIGURATION  120 V US / 230 V EU AC options

[Start your project ↗](https://ke.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | AC options (kW) |
| --- | --- | --- |
| TA6000-M2 | 10.24 | 6–10 |
| TA6000-M3 | 15.36 | 6–12 |
| TA6000-M4 | 20.48 | 6–12 |

Specify the correct market AC voltage and 50 / 60 Hz option. PV input: 11 kW for M2; 11–13.2 kW for M3/M4. No three-phase or split-phase capability is claimed.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TA6000-M2 | 590 × 570 × 1880 / W × D × H | 244 |
| TA6000-M3 | 590 × 570 × 1880 / W × D × H | 286 |
| TA6000-M4 | 590 × 570 × 1880 / W × D × H | 328 |

Communication: RS485 / RS232 / CAN / Wi-Fi; Bluetooth optional
Temperature: Operating −20 to 60 °C

## A highland home and a coastal home have different storage needs.

Kenya spans temperate highlands, hotter humid coastal areas and arid or semi-arid lowlands. Plan a useful energy reserve around your household loads, then choose the battery format and a protected equipment space for your particular location.

Temperature:  Operating −20 to 60 °C

ENCLOSURE  Not specified

01

### Highland home with a dedicated service room

For a home office, refrigeration and selected lights, a dry indoor utility space can keep the system close to the circuits it serves and leave straightforward service access.

An EU integrated system brings battery and inverter together. A TR Pro 51.2 V battery can instead work with a confirmed compatible existing inverter; size energy for the hours you choose and retain the selected model’s clearances.

Which circuits and backup hours would you like to plan for?

- What are the minimum and maximum temperatures inside the proposed room?

02

### Coastal home with a sheltered equipment area

The hotter, more humid coast calls for attention to a room’s airflow, rain exposure and coastal air. A protected service room gives refrigeration, fans and connectivity a practical installation setting.

TR Pro provides compact 51.2 V storage; HP Ultra provides a modular high-voltage format. Both list IP66. Select the architecture to match the inverter, with shelter and environmental conditions reviewed for the exact model.

Can rain, condensation, wash water or coastal air reach the equipment?

- Is the inverter a 51.2 V or high-voltage battery system?

03

### Warmer inland site with more dust exposure

In a warmer or dusty inland location, an enclosed dry equipment area with clear airflow helps keep the battery installation accessible and protected from everyday activity.

Choose wall or floor-mounted storage to suit available service space. Review the actual enclosure option and room temperature: standard TR and HP K list IP20 with IP54 optional, while HP Ultra needs its temperature range confirmed for the selected configuration.

How will dust ingress and the room’s heat be managed?

- Can cooling paths, fixing points and power/communication routes remain clear?

Specifications

- Pair energy and power: kWh helps plan duration, while the compatible inverter’s kW rating, battery limits and starting-load capability determine which circuits can run together.

- TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature limits require configuration-specific confirmation. Check the room, rather than a national temperature label.

- Specify shelter and the exact enclosure. IP66 does not itself establish flood, condensation or coastal-corrosion suitability; source temperature limits do not guarantee full output at every temperature.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The supplied brochure provides two labelled connection/breaker insets and internal cabinet/cell illustrations on printed pages 15-16. Crops avoid visible product logos without AI editing, repainting, or invented structure. Embedded views not visibly matched to the printed product page were excluded. These views do not establish pinouts, cable sizes, commissioning steps or installation compatibility.

[![Original terminal labels](https://ke.elvorka.com/assets/product-details/ta-terminal-map.png)](https://ke.elvorka.com/assets/product-details/ta-terminal-map.png)

Original terminal labels  Connection panel labelled for load, grid, optional generator, PV and communication.

[![Terminal panel close-up](https://ke.elvorka.com/assets/product-details/ta-terminal-closeup.png)](https://ke.elvorka.com/assets/product-details/ta-terminal-closeup.png)

Terminal panel close-up  Close-up of the cabinet terminal panel.

[![Original breaker labels](https://ke.elvorka.com/assets/product-details/ta-breaker-map.png)](https://ke.elvorka.com/assets/product-details/ta-breaker-map.png)

Original breaker labels  Battery, PV1, PV2, load and grid breakers in the illustrated compartment.

[![Breaker compartment close-up](https://ke.elvorka.com/assets/product-details/ta-breaker-closeup.png)](https://ke.elvorka.com/assets/product-details/ta-breaker-closeup.png)

Breaker compartment close-up  Circuit breakers within the cabinet's breaker compartment.

[![Upper cabinet and service bay](https://ke.elvorka.com/assets/product-details/ta-service-bay.png)](https://ke.elvorka.com/assets/product-details/ta-service-bay.png)

Upper cabinet and service bay  Upper cabinet compartment with the inverter and connection area.

[![Cell assembly detail](https://ke.elvorka.com/assets/product-details/ta-cell-assembly.png)](https://ke.elvorka.com/assets/product-details/ta-cell-assembly.png)

Cell assembly detail  Battery cell tops in a partial internal illustration.

### Know your interfaces.

#### Power connections

Load Output  Output position identified as Load Output in the brochure.

Grid Input  Connection position identified as Grid Input.

Generator Input (optional)  The generator input is explicitly marked optional in the original callout.

PV Input  PV connection area identified by the original callout.

PV1 Input Breaker  Breaker identified for PV1 Input.

PV2 Input Breaker  Breaker identified for PV2 Input.

#### Communication

Communication Port  Connection area labelled Communication Port. No protocol pin assignments are specified in this component view.

#### Controls & indicators

Battery Breaker  Breaker labelled for the battery section.

Load Breaker  Breaker identified for the load connection.

Grid Breaker  Breaker identified for the grid connection.

Source: Residential ESS brochure · PDF page 8 · printed pages 15-16

---

https://ke.elvorka.com/en/products/ta6000/