# TB rack.

![TB rack](https://ke.elvorka.com/assets/optimized/2b8fe35077745c40-1584-q92.webp)

Low-voltage battery

# TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20

NOMINAL ENERGY  5.12–16.076 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://ke.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Rated DC (kW) |
| --- | --- | --- |
| TB4000X | 5.12 | 5 |
| TB6000X | 10.24 | 10 |
| TB8000X | 14.336 | 10 |
| TB8500X | 16.076 | 10 |

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TB4000X | 482 × 178 × 420 / W × H × D | 42 |
| TB6000X | 482 × 223 × 550 / W × H × D | 78 |
| TB8000X | 482 × 223 × 710 / W × H × D | 109.5 |
| TB8500X | 482 × 223 × 710 / W × H × D | 112 |

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

## A highland home and a coastal home have different storage needs.

Kenya spans temperate highlands, hotter humid coastal areas and arid or semi-arid lowlands. Plan a useful energy reserve around your household loads, then choose the battery format and a protected equipment space for your particular location.

Temperature:  Charge 0 to 55 °C; discharge −20 to 60 °C

ENCLOSURE  IP20

01

### Highland home with a dedicated service room

For a home office, refrigeration and selected lights, a dry indoor utility space can keep the system close to the circuits it serves and leave straightforward service access.

An EU integrated system brings battery and inverter together. A TR Pro 51.2 V battery can instead work with a confirmed compatible existing inverter; size energy for the hours you choose and retain the selected model’s clearances.

Which circuits and backup hours would you like to plan for?

- What are the minimum and maximum temperatures inside the proposed room?

02

### Coastal home with a sheltered equipment area

The hotter, more humid coast calls for attention to a room’s airflow, rain exposure and coastal air. A protected service room gives refrigeration, fans and connectivity a practical installation setting.

TR Pro provides compact 51.2 V storage; HP Ultra provides a modular high-voltage format. Both list IP66. Select the architecture to match the inverter, with shelter and environmental conditions reviewed for the exact model.

Can rain, condensation, wash water or coastal air reach the equipment?

- Is the inverter a 51.2 V or high-voltage battery system?

03

### Warmer inland site with more dust exposure

In a warmer or dusty inland location, an enclosed dry equipment area with clear airflow helps keep the battery installation accessible and protected from everyday activity.

Choose wall or floor-mounted storage to suit available service space. Review the actual enclosure option and room temperature: standard TR and HP K list IP20 with IP54 optional, while HP Ultra needs its temperature range confirmed for the selected configuration.

How will dust ingress and the room’s heat be managed?

- Can cooling paths, fixing points and power/communication routes remain clear?

Specifications

- Pair energy and power: kWh helps plan duration, while the compatible inverter’s kW rating, battery limits and starting-load capability determine which circuits can run together.

- TR Pro lists charging at 0 to 55 °C and discharging at −20 to 60 °C; EU lists charging at 0 to 55 °C and discharging at −20 to 55 °C. HP Ultra’s temperature limits require configuration-specific confirmation. Check the room, rather than a national temperature label.

- Specify shelter and the exact enclosure. IP66 does not itself establish flood, condensation or coastal-corrosion suitability; source temperature limits do not guarantee full output at every temperature.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

[![Original front terminal and control strip](https://ke.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://ke.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)

Original front terminal and control strip  Front terminal and control strip, with the negative terminal left and positive terminal right.

[![Negative power terminal, front left](https://ke.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://ke.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)

Negative power terminal, front left  Negative terminal and minus mark at the front left.

[![Positive power terminal, front right](https://ke.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://ke.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)

Positive power terminal, front right  Positive terminal and plus mark at the front right.

[![Original communication and control area](https://ke.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://ke.elvorka.com/assets/product-details/tb-rack-communication-controls.png)

Original communication and control area  Communication connectors, indicators and power switch on the front control strip.

[![Original cell and BMS construction detail](https://ke.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://ke.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)

Original cell and BMS construction detail  Partial internal illustration showing battery cells and the BMS board.

### Know your interfaces.

#### Power connections

Positive power terminal  Power port on the viewer's right in the illustrated front panel, with the original plus mark.

Negative power terminal  Power port on the viewer's left in the illustrated front panel, with the original minus mark.

#### Communication

Dry Connect (source label)  Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.

COM0 / COM1 parallel ports  Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.

CAN / RS485  Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.

RS232  Communication port named RS232; exact pinout and adapter requirements are not provided.

#### Controls & indicators

Power switch  Power on/off switch as described in the original caption. Operating sequence is not supplied.

SOC / ALM / RUN indicators  Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.

Address identification control  Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

#### Structure & mounting

Laser welding  The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.

Steel holder  Internal steel holder identified as fixing the cells; not an external connector.

Plastic steel belt (source wording)  Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.

Built-in smart BMS  Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.

Portable handle  Steel handle as described in the source. It is not an electrical port.

Source: Residential ESS brochure · PDF page 7 · printed pages 13-14

---

https://ke.elvorka.com/en/products/tb-rack/