Betri ya volteji ya chini

# TB rack.

Uwezo nne wa betri ya LFP uliobainishwa kwa hifadhi ya rakini na inverter ya nje inayooana.

INVERTER  Inverter ya nje inayooana inahitajika

GANDA  IP20

NISHATI NOMINALI  5.12–16.076 kWh

VOLTEJI YA BETRI  DC nominali ya 51.2 V

[Anza mradi wako ↗](https://ke.elvorka.com/sw/#enquiry)

## Vipimo

| Modeli / mpangilio | Nishati (kWh) | DC iliyokadiriwa (kW) |
| --- | --- | --- |
| TB4000X | 5.12 | 5 |
| TB6000X | 10.24 | 10 |
| TB8000X | 14.336 | 10 |
| TB8500X | 16.076 | 10 |

Wi-Fi / Bluetooth imeorodheshwa kwa TB6000X, TB8000X na TB8500X, bila TB4000X. Viwango vya nguvu ni vya DC ya betri.

| Modeli | Vipimo vya ukubwa (mm) | Takriban kg |
| --- | --- | --- |
| TB4000X | 482 × 178 × 420 / W × H × D | 42 |
| TB6000X | 482 × 223 × 550 / W × H × D | 78 |
| TB8000X | 482 × 223 × 710 / W × H × D | 109.5 |
| TB8500X | 482 × 223 × 710 / W × H × D | 112 |

Mawasiliano: RS485 / CAN / RS232
Joto: Kuchaji 0 hadi 55 °C; kutoa nishati −20 hadi 60 °C

## Nyumba ya nyanda za juu na ya pwani zina mahitaji tofauti ya uhifadhi.

Kenya ina nyanda za juu zenye hali ya wastani, pwani yenye joto na unyevunyevu zaidi, na maeneo tambarare kame au nusu kame. Panga akiba ya nishati kwa vifaa vya nyumbani, kisha chagua umbo la betri na eneo la vifaa lililolindwa kulingana na mahali ulipo.

Joto:  Kuchaji 0 hadi 55 °C; kutoa nishati −20 hadi 60 °C

GANDA  IP20

01

### Nyumba ya nyanda za juu yenye chumba cha huduma

Kwa ofisi ya nyumbani, friji na taa teule, chumba kikavu cha huduma kinaweza kuweka mfumo karibu na saketi zinazohudumiwa na kuacha nafasi nzuri ya kuufikia.

Mfumo jumuishi wa EU unaweka betri na inverter pamoja. Badala yake, betri ya TR Pro ya 51.2 V inaweza kutumika na inverter iliyopo iliyothibitishwa kuoana; panga nishati kulingana na saa unazohitaji na uache nafasi za modeli husika.

Unataka kupanga kwa saketi zipi na saa ngapi za umeme wa akiba?

- Joto la chini na la juu ndani ya chumba kinachopendekezwa ni lipi?

02

### Nyumba ya pwani yenye eneo la vifaa lililokingwa

Pwani yenye joto na unyevunyevu zaidi inahitaji kuzingatia mtiririko wa hewa, mvua na hewa ya bahari. Chumba cha huduma kilicholindwa hutoa eneo linalofaa kupanga usakinishaji kwa friji, feni na mawasiliano.

TR Pro hutoa uhifadhi wa 51.2 V wenye umbo dogo; HP Ultra hutoa mfumo wa moduli za volti ya juu. Zote zina IP66. Chagua mfumo unaolingana na inverter, huku kinga na mazingira yakitathminiwa kwa modeli halisi.

Je, mvua, matone ya unyevunyevu kwenye vifaa, maji ya kusafisha au hewa ya bahari vinaweza kufikia vifaa?

- Je, inverter hutumia mfumo wa betri wa 51.2 V au volti ya juu?

03

### Eneo la ndani lenye joto au vumbi zaidi

Katika eneo la ndani lenye joto au vumbi zaidi, chumba kikavu kilichofungwa chenye njia wazi za hewa husaidia kufanya usakinishaji ufikike na ulindwe dhidi ya shughuli za kila siku.

Chagua betri ya ukutani au ya sakafuni kulingana na nafasi ya huduma. Tathmini ganda halisi na joto la chumba: TR ya kawaida na HP K zina IP20, na IP54 ni chaguo; mipaka ya joto ya HP Ultra inahitaji kuthibitishwa kwa mpangilio uliochaguliwa.

Vumbi na joto la chumba vitadhibitiwaje?

- Je, njia za hewa, sehemu za kufunga na njia za nguvu/mawasiliano zinaweza kubaki wazi?

Vipimo

- Linganisha nishati na nguvu: kWh husaidia kupanga muda, huku kiwango cha kW cha inverter inayooana, mipaka ya betri na uwezo wa kuanzisha vifaa vikiamua saketi zinazoweza kufanya kazi kwa pamoja.

- TR Pro ina kiwango cha kuchaji cha 0 hadi 55 °C na kutoa nishati cha −20 hadi 60 °C; EU ina kuchaji kwa 0 hadi 55 °C na kutoa nishati kwa −20 hadi 55 °C. Mipaka ya joto ya HP Ultra inahitaji uthibitisho wa mpangilio husika. Tathmini chumba badala ya kutegemea hali ya joto ya nchi kwa ujumla.

- Bainisha kinga na ganda halisi. IP66 pekee haithibitishi kufaa kwa mafuriko, matone ya unyevunyevu kwenye vifaa au kutu ya pwani; mipaka ya joto ya chanzo haidhamini pato kamili kwa kila joto.

MAELEZO YA BIDHAA / NYARAKA ZA ASILI

## Kila upande. Kila muunganisho.

Picha asili ya kipengele cha mbele na mchoro wenye lebo wa sehemu zilizotenganishwa zina tofauti za mpangilio zinazoonekana na hazijathibitishwa kuwa toleo moja la kifaa. Hifadhi utambulisho wa chanzo cha kila picha asili. Chanzo hakina picha ya nje ya nyuma. Michoro ya ndani/joto haipaswi kuelezwa kama picha za nje za nyuma au chini.

[![Ukanda wa asili wa terminali na vidhibiti vya mbele](https://ke.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://ke.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)

Ukanda wa asili wa terminali na vidhibiti vya mbele  Ukanda wa mbele wa vituo na udhibiti, kituo hasi kikiwa kushoto na kituo chanya kulia.

[![Terminali hasi ya nguvu, mbele kushoto](https://ke.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://ke.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)

Terminali hasi ya nguvu, mbele kushoto  Kituo hasi na alama ya kutoa mbele kushoto.

[![Terminali chanya ya nguvu, mbele kulia](https://ke.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://ke.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)

Terminali chanya ya nguvu, mbele kulia  Kituo chanya na alama ya kuongeza mbele kulia.

[![Eneo la asili la mawasiliano na udhibiti](https://ke.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://ke.elvorka.com/assets/product-details/tb-rack-communication-controls.png)

Eneo la asili la mawasiliano na udhibiti  Viunganishi vya mawasiliano, viashiria na swichi ya nguvu kwenye ukanda wa udhibiti wa mbele.

[![Maelezo ya asili ya muundo wa seli na BMS](https://ke.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://ke.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)

Maelezo ya asili ya muundo wa seli na BMS  Mchoro unaoonyesha sehemu ya ndani yenye seli za betri na bodi ya BMS.

### Vijue viunganishi vyako.

#### Miunganisho ya nguvu

Terminali chanya ya nguvu  Mlango wa nguvu upande wa kulia wa mtazamaji kwenye paneli ya mbele iliyoonyeshwa, wenye alama ya kujumlisha ya asili.

Terminali hasi ya nguvu  Mlango wa nguvu upande wa kushoto wa mtazamaji kwenye paneli ya mbele iliyoonyeshwa, wenye alama ya kutoa ya asili.

#### Mawasiliano

Dry Connect (lebo ya chanzo)  Chanzo kinautaja kama mlango wa mawasiliano wenye lebo 'Dry Connect'. Utaratibu wa kontakti, mpangilio wa pini na viwango vya umeme havijatolewa.

Milango ya sambamba ya COM0 / COM1  Milango imetajwa wazi kama 'Parallel Port' katika chanzo hiki. Mipaka ya mfumo wa sambamba na uunganishaji wa waya havijatolewa.

CAN / RS485  Kundi la milango ya mawasiliano linaloitwa CAN/RS485. Mwonekano pekee hauthibitishi mtandao wa Ethernet au itifaki ya inverter inayooana.

RS232  Mlango wa mawasiliano unaoitwa RS232; mpangilio halisi wa pini na mahitaji ya adapta havijatolewa.

#### Vidhibiti na viashirio

Swichi ya nguvu  Swichi ya kuwasha/kuzima nguvu kama ilivyoelezwa kwenye maelezo ya asili. Mfuatano wa matumizi haujatolewa.

Viashirio vya SOC / ALM / RUN  Kundi la taa za viashirio lililotambuliwa katika chanzo. Maana za kila rangi na misimbo ya uchunguzi hazijabainishwa.

Kidhibiti cha utambuzi wa anwani  Kidhibiti chenye lebo 'Add'; maelezo yanasema utambuzi wa anwani wa kiotomatiki. Njia ya kusanidi na utaratibu wa anwani havijabainishwa.

#### Muundo na kufunga

Ulehemu wa leza  Brosha inaeleza ulehemu wa leza kwa kuunganisha bamba la alumini na seli. Ni kipengele cha muundo wa ndani, si mlango.

Kishikizi cha chuma  Kishikizi cha ndani cha chuma kilichotambuliwa kuwa kinafunga seli; si kiunganishi cha nje.

Ukanda wa chuma wa plastiki (maneno ya chanzo)  Ukanda wa kushikilia seli ulioelezwa katika chanzo kuwa unazuia migongano inayotokana na kutikisika; utendaji wa nyenzo haujathibitishwa kwa kujitegemea.

BMS mahiri iliyojengwa ndani  BMS iliyojengwa ndani. Mtengenezaji anaorodhesha ulinzi wa joto, ulinzi wa saketi fupi na usawazishaji; uchimbaji huu wa taarifa hauthibitishi kazi hizo kwa kujitegemea.

Kishikio cha kubebea  Kishikio cha chuma kama kilivyoelezwa katika chanzo. Si mlango wa umeme.

Chanzo: Brosha ya ESS ya Makazi · ukurasa wa PDF 7 · kurasa zilizochapishwa 13-14

---